WQMS For (Sparing) (MTI.WQMS.SPR.DRFN) Monitor your company's wastewater management and comply with the regulations of the Ministry of Environment and Forestry (KLHK). Allow us to assist you in implementing a Continuous and Networked Wastewater Quality Monitoring System (Sparing)
WQMS For (Sparing)
Chemical Oxygen Demand (COD) (COD UV351H)
• Measuring Principle: UV254 Absorption Method
• Optical path: 2mm
• Measuring Range: COD: 1~1500mg/L;TOC: 0.4~600mg/L
• Resolution: COD: 0.01mg/L TOC: 0.1mg/L
• Accuracy: ± 3% of the measurement + 0.5mg/L
• Related Measurement: TU: 0~300NTU accuracy: ± 5% TU: 0~1000NTU accuracy: ±5%Response Time >1min
• Operating Tempe: 0~45℃ (does not freeze)
• Storage Temp: -10~60℃
• Calibration Method: Standard solution
• Protection Grade: IP68
• Working Pressure: ≤1bar
• Flow Rate: not depend on
• Power: DC 12V~24V
• Communication: RS485, Modbus RTU protocol
• Dimension: Diameter 60mm, length 215mm
• Lead Interface: M16
• Installation: Investment, 1 inch NPT pipe thread
• Shell Material: POM and 316L
• Power Consumption:
- Normal measurement: 0.1W;
- Automatic cleaning by mechanical wiper: 3W;
- Abnormal jamming of mechanical wiper: 4.5W
• Weight 720g
pH (pH DPH 790)
• Model: DPH790
• Electrical Isolation: Luminescence optical measurement
• Measuring Range: Dissolved oxygen: 0.00~20.00mg/L
• Saturation: 0~200%
• Temp: 0~50°C
• Resolution: Dissolved oxygen: 0.01mg/L Saturation: 1% Temp: 0.1°C
• Accuracy: Dissolved oxygen: ±0.3mg/L
• Saturation: ±3%
• Temp: 5~45°C
• Response Time: T90<60s
• Digital Output: RS485, Modbus RTU
• Related Compensation: Temperature/salinity/pressure compensation
• Calibration: Zero and span calibration
• Sample Flow Rate: Not dependent
• Work Pressure: 0~6Bar
• Work Temp: 0~50°C
• Storage Temp: -10~60°C
• Material: Titanium alloy
• Power Supply: DC 6~12V
• Consumption: 0.1W
• Dimensions: Diameter: 22mm Length: 160mm
• Installation: Submersible; Thread specifications: M22*1.5mm
• Lead Interface: M16
• Protection Grade: IP68
• Cable: Standard 5 meters (other length can be customized)
• Weight: 100g
• Application: Freshwater or seawater aquaculture
Amoniak - nh4 Amonium NH351 (without K-compensation)
• Model: NH351
• Measuring Principle: Ion selective electrode (ISE) method
• Measuring Range: NH4-N: 0~1000mg/L
• Accuracy: NH4-N: 5% of the measured value ± 0.2mg/L pH: 0.1pH
• Resolution: NH4-N: 0.01mg/L
• Communication: RS-485, MODBU-RTU
• Related Measurement: pH: 5.0~9.0pH (recommendation) K+: 0~1000mg/L (option)
• Response Time: T90<2min
• Temperature Range: 0~45℃ (does not freeze)
• Storage Temperature: 0~50℃ (does not freeze)
• Working Pressure: ≤1ba
• Sample Flow Rate: 0.5m/s≥flow rate≥0.001m/s
• Protection Grade: IP68
• Calibration Method: Standard solution
• Sensor Interface: Support
• Lead Interface: M16
• Shell Material: POM
• Dimension: Diameter: 65mm Length: 275mm
• Installation: Investment, 1 inch NPT pipe thread
• Power Consumption: Normal measurement: 0.6W;
• Weight: 620g
Total Suspended Solid (TSS) (OPT850)
• Model: OPTU850Z
• Electrical Isolation: Electrical isolated communication and power interfaces
• Measuring Technology Infrared scattering principle
• Measuring Range: Turbidity: 0.01~1000NTU; Suspended solids: 1~3000mg/L (Only one parameter display can be selected at the same time)
• Resolution: 0.01NTU/1mg/L
• Accuracy: Better than 5% of measured value or 0.3NTU, take the larger one
• Related Configuration: Humidity alarm
• Response Time: T90<15s
• Calibration Method: Multi-point calibration; Contrast Offset; Factor offset
• Work Pressure: ≤4Bar
• Sample Flow Rate: Not dependent
• Operating Temp: 0~50℃ (does not freeze)
• Storage Temp: -10~60℃ (does not freeze)
• Shell Material: POM+SS 316L or POM+Titanium alloy
• Dimension: Diameter: 52mm length: 260 mm
• Mounting Thread: Horizontal installation, dedicated 90° mounting accessories
• Lead interface: Split M16 connector
• Protection Grade: IP68
• Power Supply: 9~24V DC
• Power Consumption: 0.6W
• Weight: 700g