WQMS For (Onlimo) (MTI.WQMS.PBS.MP301) Online Monitoring, or Onlimo, is a continuous, automatic, and online water quality monitoring system through an application, connected to the KLHK server system. The presence of Onlimo provides significant support in obtaining real-time water quality data and enables rapid detection of changes in water quality status
WQMS For (Onlimo)
Suspended Solid (PSS-800)
• Measurement range: 0.01-20000mg/L, 0.01-45000mg/L, 0.01-120000mg/L
• Measurement accuracy: Less than the ±5% of measured value. (Depending on the homogenety of sludge)
• Pressure rate: ≤0.4Mpa
• Flow rate: ≤2.5m/s, 8.2ft/s
• Calibration: Sample Calibration, Slope Calibration
• Main material: Body: SUS316L + PVC (Normal version), SUS316L titanizing + PVC (Sea version); O-ring; flourine rubber; Cable; PVC
• Power supply: 100-240VAC (50/60hz)
• Output: 3-way 4-20mA
• Relay: Setting three-way relays, programmed response parameter and response value.
• Communication protocol: MODBUS RS485
• Storage temperature: -15°C-65°C
• Operation temperature: 0-45°
• Dimensions: Sensor: Dia 60mm*Length 256mm Transmitter: 145*125*162mm(L*W*H)
• Weight: Sensor: 1.65KG; Transmitter: 1.35KG
• Protective rate: Sensor: IP68/NEMA6P; Transmitter; IP65/NEMA4X
• Cable length: Standard: 10m, the maximum may be extended to 100m
Spectroscopic COD | Include COD, BOD (PUVCOD-900)
• Measuring Range
1) COD (using KHP calibration):0~2000mg/l COD (2mm)
2) 0~1000mg/l COD (5mm);0~90mg/l COD (50mm)
3) BOD (using KHP calibration):0~1500mg/l BOD(2mm)
4) 0~750mg/l BOD(5mm);0~60mg/l BOD(50mm)
• Accuracy: ±5%
• Measuring interval: Min one minute
• Pressure Range: ≤0.4Mpa
• Sensor material: SUS316L
• Power Supply: AC:85-500VAC (50/60HZ) DC:9~36VDC
• Output: 3-way 4-20mA
• Relay: Setting three-way relays,programmed response parameter and response value.
• Communication protocol: MODBUS RS485
• Storage temperature: -15-65°C
• Measuring temperature: 0-45°C
• Dimensions: Sensor:Diam 69mm*Length 380mm Transmitter:145*125*162mm(L*W*H)
• Weight: Sensor:3.2KG;Transmitter:1.35KG
• Protective rate: Sensor:IP68/NEMA6P;Transmitter:IP65/ NEMA4X • Cable length: Standard:10m,the maximum may be extended to 100m
Spectroscopic COD | Include COD, BOD (PUVCOD-600)
• Measuring Range: COD (using KHP calibration):0~500mg/l COD ;BOD (using KHP calibration):0~375mg/L BOD;TOC(using KHP calibration):0~200mg/L TOCTurbidity:10-800 NTU
• Accuracy: COD/BOD/TOC (using KHP calibration):±5%;Turbidity:±10%Repeatability 5% (using KHP calibration)
• Resolution: COD/BOD/TOC:0.01 mg/l;Turbidity:0.01NTU
• Pressure Range: ≤0.1Mpa
• Sensor material: Body:SUS316L(fresh water),Titanium alloy(Ocean marine),Cable:PURPower Supply AC:85-500VAC (50/60HZ);DC:9-36VDC
• Output: 3-way 4-20mA
• Relay: Three-way relays, programmed response parameter and response value. Communication protocol MODBUS RS485
• Storage temperature: -15-50℃
• Measuring temperature: 0-45℃(Non-freezing)
• Dimensions: Sensor:Diam 34mm*Length 217mm ;Transmitter:145*125*162mm(L*W*H)
• Weight: Sensor:0.8KG;Transmitter:1.35KG
• Protective rate: Sensor:IP68/NEMA6P;Transmitter:IP66/ NEMA4X
• Cable length: Standard:10m,the maximum may be extended to 100m
Conductivity Sensor (MP301 CE)
• Principle: A pair of platinum gauze electrode
• Range: 1us/cm-2000 us/cm(K=1), 100us/cm-100ms (K=10.0)
• Resolution: 0.1us/cm~0.01ms/cm(Depending on the range)
• Accuracy: ±3%
DO Sensor (MP301-DO)
• Principle: Fluorescence
• Range: 0 -20 mg/L;0-20 ppm;0-200%
• Resolution: 0.1%/0.01mg/l
• Accuracy: ±3% or ±0.3 mg/L, whichever is greater
pH Sensor(MP301-PH)
• Principle: Glass electrode method
• Range: 0-14 pH
• Resolution: 0.01 pH
• Accuracy: ±0.1 pH
Depth sensor (MP301-PRESS)
• Depth (Pressure)
• Principle: Pressure-sensitive Method
• Range: 0-61m(Maximum withstand pressure depth: 30M)
• Resolution: 2cm
• Accuracy: ±0.3%
Turbidity Sensor
• Principle: Light scattering method
• Range: 0-1000NTU
• Resolution: 0.1NTU
• Accuracy: ± 5% or 0.3NTU, whichever is greater
Ammonia Sensor
• Principle: Ion selection
• Range: 0.1~100mg/L-N
• Resolution: 0.01mg/L-N
• Accuracy: ±10% or ±2mg/L
Nitrate Sensor (MP-301-NO3)
• Principle: Ion selection
• Range: 0.1-3000mg/L-N Range 0.5-3000mg/L-N
• Resolution: 0.01mg/L-N Resolution 0.01mg/L-N
• Accuracy: ±5% or ±0.2mg/L Accuracy ±10% or ±0.2mg/L